GB/T 25206.2-2010 Reaction-to-fire tests for sandwich panel building systems—Part 2:Test method for large rooms
GB/T 25206.2-2010 Reaction-to-fire tests for sandwich panel building systems—Part 2:Test method for large rooms
Basic Information
Standard Code:
GB/T 25206.2-2010
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Fire prevention technology
ICS Name:
The flammability and combustion performance of materials and products
Publish Date:
2010-09-26
Implement Date:
2011-02-01
Pages:
14 pages
Scope
This part of GB/T 25206 specifies the test method for evaluating the combustion performance of composite sandwich panels in buildings. By simulating indoor fire conditions, the flame propagation characteristics on the surface or inside of the composite sandwich panels in buildings are evaluated by directly applying a specific flame to the products in the corners of the building rooms. This test is not used to evaluate the fire resistance of the products.
This part stipulates that the composite sandwich panels in buildings can adopt self-supporting and frame-supporting structures, but it is only applicable to testing the wall, ceiling, or roof structures of buildings.
Development Information
Referenced Standards
ISO 13943
IEC 60584-2
Adopt standards
ISO 13784-2:2002
Related Standards
GB/T 7633-1987
Replaced
GB/T 8332-1987
Replaced
GB/T 8332-1987 Test method for flammability of cellular plastics—Horizontal burning method
GB/T 8333-1987
Replaced
GB/T 8333-1987 Test method for flammability of rigid cellular plastics—Virtical burning method
GB/T 8323-1987
Replaced
GB/T 8323-1987 Test method for flammability of plastics—Smoke density test
GB/T 13488-1992
Replaced
GB/T 13488-1992 Rubber—Determination of the burning behaviour of vertical specimens
GB/T 13489-1992
Replaced