T/CIECCPA 017-2023 Active
T/CIECCPA 017-2023 Biomass boiler energy efficiency and environmental testing methods
Abstract
Main technical content: This document specifies the terms and definitions, general principles, test preparation, test requirements, test items, test methods, calculation of boiler thermal efficiency, and initial emission tests of air pollutants for biomass boilers. This document is applicable to steam boilers with a rated steam pressure greater than or equal to 0.1 MPa but less than 3.8 MPa, and a designed normal water level water capacity greater than or equal to 30 L; hot water boilers with a rated water outlet pressure less than 3.8 MPa and a rated thermal power greater than or equal to 0.1 MW; and organic heat carrier boilers with a rated thermal power greater than or equal to 0.1 MW.
General Product Information
| Document Type | Group standards |
|---|---|
| Standard Status | Active |
| Standard Code | T/CIECCPA 017-2023 |
| ICS | Boilers and heat exchangers |
| Implement Date | 2023-04-27 |