T/EAMA 15-2023 Active Group standards

T/EAMA 15-2023 Nominal voltage 1 kV and below ultra-flexible mineral insulated fire-resistant cables

T/EAMA 15-2023 Nominal voltage 1 kV and below ultra-flexible mineral insulated fire-resistant cables

Publish Date: 2023-08-10 Implement Date: 2023-08-10 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/EAMA 15-2023
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Electrician
ICS Name: Cable
Publish Date: 2023-08-10
Implement Date: 2023-08-10

Scope

Scope: This document specifies the terms and definitions, usage characteristics, product model specifications, technical requirements, test methods, inspection rules, marking, packaging, transportation, and storage of ultra-flexible mineral insulated fire-resistant cables with a rated voltage of 1 kV and below. This document is applicable to rated voltage of 1 kV and below ultra-flexible mineral insulated fire-resistant cables (hereinafter referred to as "cables") used in power supply and distribution lines, high-temperature environments, and locations with fire-resistance requirements; Main technical content: 3. Terms and definitions 4. Usage characteristics 5. Cable classification, code, model specifications, and representation 5.1 Classification 5.2 Code 5.3 Model and structure 5.4 Cable specifications 5.5 Product representation method 6. Technical requirements 6.1 Conductor 6.2 Insulation 6.3 Cable assembly 6.4 Mineral material oxygen barrier layer 6.5 Non-metallic outer sheath 7. Finished cables 7.1 Electrical performance 7.2 Mechanical and physical performance 7.3 Flame retardant performance 7.4 Smoke density test 7.5 Acidic corrosive gas test 7.6 Fire resistance test 7.7 Flammability performance grade 8. Test methods and inspection rules 9. Delivery and acceptance 10. Marking, packaging, storage, and transportation 10.1 Marking of finished cables 10.2 Packaging 10.3 Storage and transportation Appendix A (normative): Calculation method of the assumed outer diameter of cables Appendix B (informative): Reference outer diameter of cables Appendix C (normative): Test method for combustion residues of thermoplastic ceramic halogen-free low-smoke polyolefin flame-retardant fire-resistant insulation materials Appendix D (informative): Reference current-carrying capacity of rated voltage 1 kV and below ultra-flexible mineral insulated fire-resistant cables

Development Information

Related Standards