\nThe selection and use of calculation methods for absorbed dose in radiation processing according to T/CIRA 4-2019
T/CIRA 4-2019
Basic Information
Scope
Scope: This standard specifies the selection and use of Monte Carlo method, point kernel method, discrete coordinate method, empirical method, and semi-empirical method for calculating the absorbed dose in radiation processing. This standard is applicable to the calculation of the dose and distribution of gamma rays emitted by 137Cs or 60Co, electron beams generated by electron accelerators used in radiation processing, or X-rays; Main technical content: This standard mainly describes five mathematical methods for calculating absorbed dose: Chapter 4 provides a summary description of the five methods; Chapter 5 introduces the advantages and disadvantages of the five methods, so that users can compare and select the appropriate method; Chapter 6 introduces the requirements for confirming and validating the calculation results; Chapter 7 introduces the uncertainty of the calculation results, including the factors affecting the calculation results; Chapter 8 introduces the requirements for documents and records, including general requirements, document requirements, etc.; Appendix A provides the requirements for establishing and using Monte Carlo method, point kernel method, and empirical method, and provides application examples of the methods, which are of great reference significance to users.