Scope

Main technical specifications: Appearance and odor: Colorless transparent liquid, no visible mechanical impurities, and no unpleasant odor. Flash point (open cup) / °C: ≥200 Ignition point / °C: ≥235 Auto-ignition point / °C: ≥250 Thermal decomposition temperature / °C: ≥250 Boiling point (standard atmospheric pressure) / °C: ≥130 Acid value (mg KOH/g): ≤0.03 Kinematic viscosity (40°C) / (mm2/s): ≤6 Water content, w/w (%): ≤0.002 Density (20°C) / (g/cm3): 1.72–1.85 Breakdown voltage (2.5mm) / kV: ≥40 Volume resistivity / (Ω·cm): ≥1×1012 Dielectric loss factor (%): ≤0.05 Relative permittivity (10GHz): ≤2 Specific heat capacity / (J/(kg·K)): ≥960 Thermal conductivity / (W/(m·K)): >0.065 Pour point / °C: ≤-45 --- **Key translations:** 1. **Flash point (open cup)**: Translated as "flash point (open cup)" to reflect the standard testing method. 2. **Ignition point**: Translated as "ignition point" to match common engineering terminology. 3. **Auto-ignition point**: Translated as "auto-ignition point" to emphasize spontaneous combustion. 4. **Thermal decomposition temperature**: Translated as "thermal decomposition temperature" to highlight the temperature at which decomposition occurs. 5. **Boiling point (standard atmospheric pressure)**: Translated as "boiling point (standard atmospheric pressure)" to clarify the testing conditions. 6. **Acid value**: Translated as "acid value" to align with industry standards. 7. **Kinematic viscosity**: Translated as "kinematic viscosity" to emphasize flow behavior at high temperatures. 8. **Water content, w/w**: Translated as "water content, w/w (%)" to clarify the measurement method. 9. **Density**: Translated as "density" to match common engineering terminology. 10. **Dielectric loss factor**: Translated as "dielectric loss factor" to emphasize electrical properties. 11. **Relative permittivity**: Translated as "relative permittivity" to describe the electrical response o

Development Information

Related Standards

Contact Us