T/SDBDA 7-2021 Active Group standards

T/SDBDA 7-2021 Remote dynamic electrocardiogram diagnosis service specification

T/SDBDA 7-2021 Remote dynamic electrocardiogram diagnosis service specification

Publish Date: 2021-01-25 Implement Date: 2021-01-25 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/SDBDA 7-2021
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Medical devices
ICS Name: Integrated medical science and healthcare devices
Publish Date: 2021-01-25
Implement Date: 2021-01-25

Scope

Main Technical Content: 4. Remote Diagnosis Institution Requirements 4.1.1 Network Environment Requirements - The network should be high-speed, with high-speed transmission networks between any two points. The network architecture and devices should have strong interoperability to ensure the stability and reliability of the network and computer systems. - High-tech reliability technologies are used to implement redundant backup of physical network links and provide high-performance services for point-to-point connections. When a line fails, data can be transmitted via backup links to ensure normal system operation. - Network devices and system platforms should be easy to install, configure, and use. Servers are configured by region, with a central server for backend operations. Network load is reasonably allocated and adjusted to monitor network status and prevent traffic congestion, ensuring smooth network operation. - Comprehensive security measures are implemented, including strict management of hardware, software, and administrative aspects to prevent unauthorized access and data leaks. 4.1.2 Software Architecture Requirements - The system should be built based on the Service-Oriented Architecture (SOA) concept. - It adopts the B/S model and is deployed according to the optimal network solution based on different application environments. - It complies with existing standard framework protocols and industry-standard agreements. - It uses open-standard design to ensure compatibility with other medical systems and devices. - It meets future development needs and provides ample room for expansion. - Components closely related to SOA reusability, such as service interfaces, should use mature technical standards. - For unfinalized de facto standards or specifications, they can be used as optional technical references. - The remote medical information system should have message routing capabilities, enable business process management, su

Development Information

Related Standards

Contact Us