T/ZJGS 17-2022 Active Group standards

T/ZJGS 17-2022 Passive Smart Lock, Part 1: Passive Contact Power Supply

T/ZJGS 17-2022 Passive Smart Lock, Part 1: Passive Contact Power Supply

Publish Date: 2022-06-18 Implement Date: 2022-08-18 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/ZJGS 17-2022
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: -
ICS Name: Other household and commercial equipment
Publish Date: 2022-06-18
Implement Date: 2022-08-18

Scope

Main Technical Content: 7.2 Functions 7.2.1 Self-Check Function When the passive padlock starts working, it should indicate or display that it is operating normally. 7.2.2 Login Function According to the steps specified in the product manual, it should be able to log in user information. 7.2.3 Delete Function According to the steps specified in the product manual, it should be able to delete logged-in user information. 7.2.4 Information Storage Function When the power supply is cut off or the battery is replaced, the information stored in the electronic key should not be lost. 7.2.5 User Permission Management Function It should have a hierarchical user permission management function, and there should be a corresponding authorization mechanism during the process of adding and deleting users. 7.3 Enclosure Protection Level The protection level of the passive padlock enclosure should comply with Table 2. 7.4 Flexibility 7.4.1 Information Response Time The opening response time should not exceed 2 seconds. 7.4.2 Key Opening Operation The key opening operation should be flexible. The key opening torque M1 should not exceed 1 N·m, and the lock beam should be able to open. 7.4.3 Key Insertion and Removal Force The key insertion and removal force should not exceed 10 N. 7.4.4 Lock Beam Downward Closing Force The lock beam downward closing force should not exceed 70 N. 7.5 Strength 7.5.1 Lock Beam Tensile Strength After withstanding the tensile force F1 specified in Table 2, the passive padlock should not be opened. 7.5.2 Lock Beam Torsion Moment After withstanding the torsion moment M2 specified in Table 2, the passive padlock should not be opened. 7.5.3 Lock Beam Anti-Shearing After withstanding the shearing force F2 specified in Table 2, the lock beam should not be cut off. 7.5.4 Impact Resistance After withstanding the impact force specified in Table 2, it should not be opened. 7.5.5 Anti-Sawing After reac

Development Information

Related Standards