T/BEA 43011-2024 Active Group standards

T/BEA 43011-2024 Remote calibration method for oscilloscope

T/BEA 43011-2024 Remote calibration method for oscilloscope

Publish Date: 2024-08-01 Implement Date: 2024-08-21 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/BEA 43011-2024
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: -
ICS Name: Integrated Metrology and Measurement
Publish Date: 2024-08-01
Implement Date: 2024-08-21

Scope

Scope: This method specifies the relevant content of remote testing for oscilloscopes, including the items of remote testing for oscilloscopes and the remote testing process, etc. This method is applicable to the remote testing of oscilloscope devices within the DSO series of Keysight and the TDS series of Tektronix; Main technical content: 4 Remote testing conditions: An overview of the environmental conditions and testing equipment for remote testing of oscilloscopes; 4.1 Environmental conditions (1) Environmental temperature: (20 ± 5) °C; (2) Relative humidity: ≤80%; (3) Power supply voltage: 220 (1 ± 5) V, 50 ± 1 Hz; (4) No electromagnetic interference or mechanical vibration in the surrounding environment that may affect the normal operation of the instrument. 4.2 Testing equipment (1) Signal generator: PXIe-5654RF; (2) Digital multimeter: PXIe-4137; (3) Power meter: USB-5681; (4) Timing generator: PXIe-6674T; (5) DC source module: PXIe-4137; (6) Programmable computer: Windows operating system. 5 Remote testing method steps 5.1 Hardware operation steps (1) Equipment preparation: Ensure that the oscilloscope, signal generator, digital multimeter, power meter, DC source module, and programmable computer are all in good working condition. Check whether all connection cables (GPIB bus, network cable, etc.) are intact and ensure that they can correctly connect to each device. (2) Device connection: Use GPIB bus or network cables to connect the oscilloscope, standard instruments, and programmable computers. Ensure that the connections are correct and check the communication status of the devices to ensure that they can communicate normally. (3) Environmental setting adjustment: Adjust the testing environment to ensure that the temperature, humidity, AC power supply, and other conditions meet the requirements of the testing protocol. Eliminate possible electromagnetic interference and mechanical vibration in the surrounding environment that may affect the testing work

Development Information

Related Standards

Contact Us