Scope

Scope: This standard specifies the requirements for the site selection, general layout, process and facilities, fire protection facilities and water supply and drainage, electrical systems, instrumentation, alarm and emergency shutdown systems, building and heating ventilation, construction acceptance, and operation and maintenance of LNG tank container (hereinafter referred to as "tank container") vaporization stations. This standard applies to the design, construction, acceptance, and operation and maintenance of LNG tank containers with a total storage volume not exceeding 184m3 (geometric volume). This document does not apply to the design, construction, acceptance, and operation and maintenance of the following plants and stations: - LNG tank container vaporization stations built in conjunction with compressed natural gas supply stations, liquefied petroleum gas supply stations, gas filling stations, and fuel stations, etc.; - LNG tank container vaporization stations with LNG cylinder filling functions. Main technical content: 1. Scope: This standard specifies the requirements for the site selection, general layout, process and facilities, fire protection facilities and water supply and drainage, electrical systems, instrumentation, alarm and emergency shutdown systems, building and heating ventilation, construction acceptance, and operation and maintenance of LNG tank container (hereinafter referred to as "tank container") vaporization stations. This standard applies to the design, construction, acceptance, and operation and maintenance of LNG tank containers with a total storage volume not exceeding 184m3 (geometric volume). This document does not apply to the design, construction, acceptance, and operation and maintenance of the following plants and stations: - LNG tank container vaporization stations built in conjunction with compressed natural gas supply stations, liquefied petroleum gas supply stations, gas filling stations, and fuel stations, etc.; -

Development Information

Related Standards

Contact Us