T/GDWCA 0099-2022 Active Group standards

T/GDWCA 0099-2022 The rated voltage is 600V and below, and the high-temperature wire used for FEP/PFA insulated installation

T/GDWCA 0099-2022 The rated voltage is 600V and below, and the high-temperature wire used for FEP/PFA insulated installation

Publish Date: 2022-07-01 Implement Date: 2022-08-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Download

Basic Information

Standard Code: T/GDWCA 0099-2022
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: -
ICS Name: Cable
Publish Date: 2022-07-01
Implement Date: 2022-08-01
Pages: 26 pages

Scope

Main technical content: This document specifies the classification and naming, structural requirements, finished product testing requirements, marking, testing methods, and technical requirements of high-temperature wires (hereinafter referred to as wires) insulated with fluorinated ethylene propylene (FEP) and meltable polytetrafluoroethylene (PFA) for rated voltages of 600V and below. This document is applicable to wires with a nominal conductor cross-sectional area of 0.051mm2 to 25.0mm2, rated temperatures of 150℃, 200℃, and 250℃, and AC rated voltages of 30V, 60V, 90V, 125V, 150V, 300V, and 600V. These wires can be used for the installation of electrical equipment in fields such as iron and steel smelting, temperature sensing, household appliances, information technology, lighting industry, and instrumentation, etc.

Development Information

Pages: 26 pages

Related Standards

Contact Us