T/SCDA 060-2021 Modular Assembly Integrated Steel Concrete Shear Wall Structure Application Technical Standards
T/SCDA 060-2021 Modular Assembly Integrated Steel Concrete Shear Wall Structure Application Technical Standards
Basic Information
Scope
Main technical content: - For solid self-insulated wallboard systems, the seismic fortification intensity is 7 degrees for 100m, and 8 degrees for 80m. - For JGJ1DG/TJO8-2071 self-insulated wallboard systems, the seismic fortification intensity is 7 degrees for 60m and 8 degrees for 40m. - For JGJ1DG/TJO8-20711 modular assembly integral high-rise shear wall structures, short shear walls should not be used exclusively. - For seismic fortification intensity of 8 degrees, shear wall structures with a large number of short shear walls should not be adopted. - When the building height exceeds 60m, a special review of seismic fortification should be conducted, and the production process and acceptance standards of prefabricated components should be specifically studied and verified. - For Class A buildings, the seismic fortification intensity should be increased by one degree in the local area.