PDF

T/CAPEC 30-2023 Active

T/CAPEC 30-2023 The technical requirements for supervision of the manufacture of insulated power cables with rated voltage of 110kV (Um=126kV) and above

Available format(s)
PDF
Language(s)
Chinese
Publish Date
2023-08-01

Abstract

Scope: This document specifies the technical requirements for the supervision of the manufacturing process of extruded insulated power cables with a rated voltage of 110 kV (Um = 126 kV) and above. This document applies to the supervision of the manufacturing of extruded insulated power cables with a rated voltage of 110 kV (Um = 126 kV) and above. The supervision of the manufacturing of submarine cables and extruded insulated power cables with a rated voltage of less than 110 kV (Um = 126 kV) can be referenced for implementation. This document does not apply to the supervision of oil-paper insulated self-contained oil-filled power cables. Main technical content: (1) This standard specifies the basic technical requirements for equipment supervision services related to the manufacturing process of extruded insulated power cables with a rated voltage of 110 kV (Um = 126 kV) and above, and is applicable to the equipment manufacturing supervision activities carried out by equipment supervision units for extruded insulated power cables with a rated voltage of 110 kV (Um = 126 kV) and above, including basic requirements for supervision services, pre-production inspections, technical document inspections, raw material and component inspections, quality supervision during the manufacturing process, witnessing of tests, progress control, and supervision information management. (2) To standardize and unify the terminology related to extruded insulated power cables with a rated voltage of 110 kV (Um = 126 kV) and above and other related terms, important terms and definitions related to the supervision of the manufacturing of extruded insulated power cables with a rated voltage of 110 kV (Um = 126 kV) and above are proposed. (3) The supervision implementation process related to manufacturing quality is clearly defined. Appendix "A" is the list of key witnessing points for the supervision of the manufacturing of extruded insulated power cables with a rated voltage of 110 kV (Um

General Product Information

Document Type Group standards
Standard Status Active
Standard Code T/CAPEC 30-2023
ICS Other services
Implement Date 2023-11-01
Price $ 20.00
Subtotal $ 20.00
Tax $ 0.00
Order Total (incl. tax) $ 20.00

Log In

Contact Us