PDF

CJ/T 449-2014 Active

CJ/T 449-2014 Diaphragm gas meter with shut-off valve

Available format(s)
PDF
Language(s)
Chinese
Publish Date
2014-03-27

Abstract

This standard specifies the terms and definitions, models, general requirements, testing methods, inspection rules, marking, packaging, transportation, and storage of cut-off type membrane gas meters (hereinafter referred to as gas meters).
This standard applies to the design, production, testing, and acceptance of gas meters with a maximum working pressure not exceeding 10 kPa, a maximum flow rate not exceeding 10 m3/h, and an adaptive minimum working temperature range of -10 ℃ to 40 ℃.

General Product Information

Document Type Industry standards-Urban construction
Standard Status Active
Standard Code CJ/T 449-2014
CCS Gas supply project
ICS Volume equipment and volume measurement
Implement Date 2014-07-01