PDF

GB/T 20975.25-2008

GB/T 20975.25-2008 Methods for chemical analysis of aluminium and aluminium alloys—Part 25:Inductively coupled plasma atomic emission spectrometric method

Available format(s)
PDF
Language(s)
Chinese
Publish Date
2008-06-09

Abstract

This method specifies the determination method for the content of iron, copper, magnesium, manganese, gallium, titanium, vanadium, indium, tin, bismuth, chromium, zinc, nickel, cadmium, zirconium, beryllium, lead, boron, silicon, strontium, calcium, and antimony in aluminum and aluminum alloys. This method is suitable for the determination of the content of iron, copper, magnesium, manganese, gallium, titanium, vanadium, indium, tin, bismuth, chromium, zinc, nickel, cadmium, zirconium, beryllium, lead, boron, silicon, strontium, calcium, and antimony in aluminum and aluminum alloys. The determination range is shown in Table 1.

General Product Information

Document Type National standards
Standard Status Replaced
Standard Code GB/T 20975.25-2008
CCS Analysis methods for light metals and their alloys
ICS Aluminum and aluminum alloys
Implement Date 2008-12-01
Price $ 44