PDF
GB/T 3410.1-2008 Active
GB/T 3410.1-2008 Instrument for dam monitoring—Joint meter—Part 1:Unbonded elastic wire resistance joint meter
Abstract
This part of GB/T 3410 specifies the product structure, specifications, and main parameters, technical requirements, test methods, inspection rules, marking and user's manual, as well as packaging, transportation, and storage for differential resistance-type crack gauges. This part is applicable to differential resistance-type crack gauges installed in various geotechnical engineering projects to monitor the displacement of structures or the opening and closing degree (deformation) of expansion joints.
General Product Information
| Document Type | National standards |
|---|---|
| Standard Status | Active |
| Standard Code | GB/T 3410.1-2008 |
| CCS | Engineering survey and geotechnical engineering |
| ICS | Geology, meteorology, and hydrology |
| Implement Date | 2008-05-01 |