PDF
GB/T 24918-2010 Active
GB/T 24918-2010 Cryogenic emergency shutoff valve
Abstract
This standard specifies the terms, technical requirements, test methods, inspection rules, appearance, marking, and supply requirements for emergency shut-off valves used for low-temperature media (hereinafter referred to as emergency shut-off valves).
This standard applies to nominal sizes DN 15 to DN 200, nominal pressures PN 16 to 63, operating temperatures of -196°C to -29°C, emergency automatic shut-off temperatures of 70°C ± 5°C, and low-temperature media such as oxygen, nitrogen, argon, natural gas, ethylene (O2, N2, Ar, CNG, C2H4), and other gases and liquids.
General Product Information
| Document Type | National standards |
|---|---|
| Standard Status | Active |
| Standard Code | GB/T 24918-2010 |
| CCS | \nValve |
| ICS | Other valves |
| Implement Date | 2010-12-31 |