T/GDAEPI 12-2022 Active
T/GDAEPI 12-2022 Technical requirements and testing methods for continuous monitoring system for non-methane volatile organic compounds (NMVOCs) emissions from fixed pollution sources using catalytic oxidation-non-dispersive infrared (NDIR) method
Abstract
Main technical content: This document specifies the principles and components, technical requirements, performance indicators, detection methods, installation requirements, detection items, technical indicator debugging and testing requirements, technical acceptance requirements, daily operation and management requirements, daily operation quality assurance requirements, data review and processing, etc. of the continuous monitoring system for non-methane hydrocarbons in fixed pollution source waste gas (catalytic oxidation - non-dispersive infrared method). This document is applicable to the design, production, and acceptance of the continuous monitoring system for non-methane hydrocarbons in fixed pollution source waste gas (catalytic oxidation - non-dispersive infrared method). The catalytic oxidation - non-dispersive infrared method is suitable for measuring waste gas emissions with a background volume concentration of carbon dioxide not exceeding 2,000μmol/mol and an oxygen content not less than 5%.
General Product Information
| Document Type | Group standards |
|---|---|
| Standard Status | Active |
| Standard Code | T/GDAEPI 12-2022 |
| ICS | Integrated Environment and Environmental Protection |
| Implement Date | 2022-12-31 |