T/GDBIA 04-2023 Active
T/GDBIA 04-2023 Electric bicycle battery fire end specification
Abstract
Main technical content: 5.6 Testing methods 5.6.1 Hydraulic-electrical integrated charging socket The testing of the hydraulic-electrical integrated charging socket includes: - Insulation test - Rated current charging and discharging test 5.6.2 Fire-extinguishing liquid bottle The testing of the fire-extinguishing liquid bottle includes: - Visual inspection and chemical reagent testing to check for leakage after filling with fire-extinguishing liquid - Vibration test and aging test 5.6.3 Control board After powering on the control board and inputting a trigger signal, the control board should perform the corresponding actions. 5.6.4 Sound and light alarm After powering on the sound and light alarm and inputting a trigger signal, it should sound an alarm and flash lights. 5.6.5 Communication and positioning module After powering on the communication and positioning module and inputting a trigger signal, the alarm signal should be immediately fed back and reported to the cloud monitoring center.
General Product Information
| Document Type | Group standards |
|---|---|
| Standard Status | Active |
| Standard Code | T/GDBIA 04-2023 |
| ICS | The comprehensive overview of batteries and storage batteries |
| Implement Date | 2023-04-01 |