T/ACEF 086-2023 Determination of 22 volatile organic compounds containing oxygen in fixed-pollutant sources emissions by gas chromatography-mass spectrometry
T/ACEF 086-2023 Determination of 22 volatile organic compounds containing oxygen in fixed-pollutant sources emissions by gas chromatography-mass spectrometry
Basic Information
Scope
Scope: This document specifies the gas chromatography-mass spectrometry method for determining 22 kinds of oxygenated volatile organic compounds, including acetaldehyde, in the exhaust gas of fixed pollution sources. This document is applicable to the determination of 22 kinds of oxygenated volatile organic compounds, including acetaldehyde, in fixed pollution sources. When the sampling volume is 1.0 mL, the method detection limits of the target compounds are 0.5 mg/m3 to 5.0 mg/m3, and the determination lower limits are 2.0 mg/m3 to 20.0 mg/m3. They shall comply with the provisions of Appendix A; Main technical content: Method principle, reagents and materials, instruments and equipment, sample analysis steps, result calculation and presentation, accuracy, quality assurance and quality control, and waste disposal precautions.