T/CECA-G 0057-2020 "Leader standard evaluation requirements for commercial refrigerators"
T/CECA-G 0057-2020 "Leader standard evaluation requirements for commercial refrigerators"
Basic Information
Scope
Main Technical Content: 4.3 Evaluation Indicator Framework for Commercial Freezers The evaluation indicator framework for the "Leader" standard for commercial freezers is shown in Table 1. Table 1: Evaluation Indicator Framework Serial Number Indicator Type Evaluation Indicator Indicator Source (Judging Criteria/Method) Indicator Level Classification Advanced Level Average Level Reference Level 1 Basic Indicators Safety GB 4706.1 GB 4706.102—Meets standard requirements Electromagnetic compatibility GB 17625.1 GB 4343.1 Restricted substance limits GB/T 26572 Other indicators, see Appendix A2 Core Indicators Energy Efficiency Index (%) GB 26920.1 GB 26920.2 —Energy Efficiency Index η≤50% Energy Efficiency Index η≤55% Energy Efficiency Index η≤65% Noise (dB(A)) SB/T 10794.2 SB/T 10794.3 For condensing units without cooling fans Power of condensing unit and fan (kW): P≤0.25 ≤51 ≤53 ≤55 Power of condensing unit and fan (kW): 0.25