GB/T 20466-2006
Active
GB/T 34322-2017
Active
National standards
GB/T 34322-2017 Automatic continuous determination of water quality for boiler and cooling system—Potentiometric titration
GB/T 34322-2017 Automatic continuous determination of water quality for boiler and cooling system—Potentiometric titration
Basic Information
Standard Code:
GB/T 34322-2017
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Basic standards and general methods for water treatment agents
ICS Name:
\nChemical testing of water
Publish Date:
2017-09-07
Implement Date:
2018-04-01
Pages:
14 pages
Scope
This standard specifies the automatic continuous measurement methods for electrical conductivity, pH, phenolphthalein alkalinity, total alkalinity, chloride ions, and hardness in water used for industrial boilers, circulating cooling water, and natural water. The measurement range applicable to this standard is: electrical conductivity of 10 μS/cm to 10 mS/cm; pH of 3 to 13; phenolphthalein alkalinity of 0 mmol/L to 30 mmol/L; total alkalinity of 0.2 mmol/L to 50 mmol/L; chloride ions of 5 mg/L to 1,500 mg/L; and hardness (calculated as Ca2+ and Mg2+) of 0.015 mmol/L to 15 mmol/L.
Development Information
Referenced Standards
GB/T 601-2002 Chemical reagent Preparations of standard volumetric solutions
GB/T 601-2016 Chemical reagent—Preparations of reference titration solutions
GB/T 6682-1992 Water for analytical laboratory use—Specification and test methods
GB/T 6682-2008 Water for analytical laboratory use—Specification and test methods
GB/T 6904-2008 Water used in industrial circulating cooling system and boiler—Determination of pH
GB/T 6904.3-1993 Analysis of water used in boiler and cooling system—Determination of pH—The glass electrode method for pure water
GB/T 6908-2005 Analysis of water used in boil and cooling system—The determination of electrical conductivity for water
GB/T 6908-2008 Analysis of water used in boil and cooling system—Determination of electrical conductivity
GB/T 6908-2018 Analysis of water used in boiler and cooling system—Determination of electrical conductivity
GB/T 6904.1-1986 Methods for analysis ofwater for boiler and for cooling--The determination of pH--The glass electrode method
GB/T 6904.2-1986 Methods for analysis of water for boiler and for cooling--The determination of pH--Colorimetric method
Related Standards
GB/T 21925-2008
Active
GB/T 21925-2008 Determination of herbicide residues in water—LC/MS method
GB/T 29340-2012
Active
GB/T 29340-2012 Analysis of water used in boil and cooling system—Determination of chloride—Ammonium thiocyanate titration method
GB/T 14420-2014
Replaced
GB/T 14420-2014 Analysis of water used in boiler and cooling system—Determination of chemical oxygen demand—Rapid method with potassium dichromate
GB/T 33086-2016
Active
GB/T 33086-2016 Water treatment chemical—Determination of arsenic and mercury—Atomic fluorescence spectrometry
GB/T 12149-2017