YS/T 547-2007 Active Industry standards-Non-ferrous metals

YS/T 547-2007 High-pure tantalum pentoxide

YS/T 547-2007 High-pure tantalum pentoxide

Publish Date: 2007-11-14 Implement Date: 2008-05-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: YS/T 547-2007
Standard Type: Industry standards
Standard Status: Active
is_force_gb: no
CCS Name: Oxides, elemental substances
ICS Name: Oxide
Publish Date: 2007-11-14
Implement Date: 2008-05-01
Pages: 6 pages

Scope

This standard specifies the requirements, test methods, inspection rules, marking, packaging, transportation, storage, and order form content for high-purity tantalum pentoxide. This standard applies to high-purity tantalum pentoxide produced by the liquid-liquid extraction method. The product is used for the production of tantalate crystals and as an additive for optical glass, among other applications.

Development Information

Word Count: 8 Thousand words Pages: 6 pages

Replace the following standards

YS/T 547-2006

Referenced Standards

GB/T 3249-1982 Standard method for determination of particle size of powders of refractory metals and compounds—Fisher method GB/T 3249-2009 Test method for Fisher number of metal powders and related compounds GB/T 3249-2022 Test method for Fisher number of metal powders and related compounds GB/T 5060-1985 Metallic powders—Determination of apparent density—Part 2:Scott volumeter method GB/T 5314-1985 Powders for powder metallurgical purposes—Sampling GB/T 5314-2011 Powders for powder metallurgical purposes—Sampling GB/T 13390-1992 Metallic powder—Determination of the specific surface area—Method of nitrogen adsorption GB/T 13390-2008 Metallic powder—Determination of the specific surface area—Method of nitrogen adsorption GB/T 15076.10-1994 Methods for chemical analysis of tantalum and niobium—Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium GB/T 15076.11-1994 Methods for chemical analysis of tantalum and niobium—Determination of arsenic antimony、lead、tinand bismuth contents in niobium GB/T 15076.1-1994 Methods for chemical analysis of tantalum and niobium—Determination of tantalum content in niobium GB/T 15076.12-1994 Methods for chemical analysis of tantalum and niobium—Determination of carbon content GB/T 15076.13-1994 Methods for chemical analysis of tantalum and niobium—Determination of nitrogen content in tantalum GB/T 15076.14-1994 Methods for chemical analysis of tantalum and niobium—Determination of oxygen content GB/T 15076.15-1994 Methods for chemical analysis of tantalum and niobium—Determination of hydrogen content GB/T 15076.2-1994 Methods for chemical analysis of tantalum and niobium—Determination of niobium content in tantalum GB/T 15076.3-1994 Methods for chemical analysis of tantalum and niobium—Determination of copper content GB/T 15076.4-1994 Methods for chemical analysis of tantalum and niobium—Determination of iron content GB/T 15076.5-1994 Methods for chemical analysis of tantalum and niobium—Determination of molybdenum and tungsten contents GB/T 15076.6-1994 Methods for chemical analysis of tantalum and niobium—Determination of silicon content in tantalum GB/T 15076.7-1994 Methods for chemical analysis of tantalum and niobium—Determination of phospherus content in niobium GB/T 15076.8-1994 Methods for chemical analysis of tantalum and niobium—Determination of sulphur content in niobium GB/T 15076.9-1994 Methods for chemical analysis of tantalum and niobium—Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper and zirconium contents in tantalum GB/T 15076.12-2008 Methods for chemical analysis of tantalum and niobium—Determination of phosphorus content in tantalum GB/T 15076.14-2008 Methods for chemical analysis of tantalum and niobium—Determination of oxygen content GB/T 15076.15-2008 Methods for chemical analysis of tantalum and niobium—Determination of hydrogen content GB/T 15076.16-2008 Methods for chemical analysis of tantalum and niobium—Determination of sodium and potassium contents GB/T 15076.8-2008 Methods for chemical analysis of tantalum and niobium—Determination of carbon and sulphur contents GB/T 15076.9-2008 Methods for chemical analysis of tantalum and niobium—Determination of iron,chromium,nickel,manganese,titanium,aluminum,copper,tin,lead and zirconium contents in tantalum GB/T 15076.1-2017 Methods for chemical analysis of tantalum and niobium—Part 1:Determination of tantalum content in niobium—Inductively coupled plasma atomic emission spectrometry GB/T 15076.13-2017 Methods for chemical analysis of tantalum and niobium—Part 13:Determination of nitrogen content—Inert gas fusion thermal conductivity method GB/T 15076.5-2017 Methods for chemical analysis of tantalum and niobium—Part 5:Determination of molybdenum and tungsten contents—Inductively coupled plasma atomic emission spectrometry GB/T 15076.3-2019 Methods for chemical analysis of tantalum and niobium—Part 3:Determination of copper content—Flame atomic absorption spectrometry GB/T 15076.10-2019 Methods for chemical analysis of tantalum and niobium—Part 10:Determination of iron,nickel,chromium,titanium,zirconium,aluminum and manganese contents in niobium—Direct current arc atomic emission spectrometry GB/T 15076.2-2019 Methods for chemical analysis of tantalum and niobium—Part 2:Determination of niobium content in tantalum—Inductively coupled plasma atomic emission spectrometry and stratography gravimetry GB/T 15076.11-2020 Methods for chemical analysis of tantalum and niobium—Part 11:Determination of arsenic,antimony,lead,tin and bismuth contents in niobium—Direct current arc atomic emission spectrometry GB/T 15076.4-2020 Methods for chemical analysis of tantalum and niobium—Part 4:Determination of iron content—1,10-Phenanthroline spectrophotometry GB/T 15076.6-2020 Methods for chemical analysis of tantalum and niobium—Part 6:Determination of silicon content—Inductively coupled plasma atomic emission spectrometry GB/T 15076.7-2020 Methods for chemical analysis of tantalum and niobium—Part 7:Determination of phospherus content in niobium—4-Formyloxy-pentyl ketone-[2]extraction separation phosphomolybdate blue spectrophotometry and inductively coupled plasma atomic emission spectrometry

Related Standards

Contact Us