JJG 351-1996 Replaced National Metrology and Inspection Regulations JJG

JJG 351-1996 Working Base Metal Thermocouple

JJG 351-1996 Working Base Metal Thermocouple

Publish Date: 1996-08-23 Implement Date: 1997-03-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: JJG 351-1996
Standard Type: National standards
Standard Status: Replaced
is_force_gb: no
CCS Name: -
ICS Name: -
Publish Date: 1996-08-23
Implement Date: 1997-03-01
Pages: 47 pages

Scope

This procedure is applicable to the verification of newly manufactured and in-use nickel-chromium-nickel silicon thermocouples with a scale number of K, nickel-chromium-silicon thermocouples with a scale number of N, nickel-chromium-copper nickel thermocouples with a scale number of E, and iron-copper nickel thermocouples with a scale number of J (hereinafter referred to as K, N, E, and J type thermocouples, respectively) with a length of not less than 750 mm, within the temperature range of -40 to 1,300 °C.

Development Information

Word Count: 65 Thousand words Pages: 47 pages

Replace the following standards

JJG 351-1984

Superseded by the following standards

Related Standards

Contact Us