T/DZJN 46-2021 Data Center Room Infrastructure Color Management Standards

T/DZJN 46-2021

Publish Date: 2021-09-26 Implement Date: 2021-11-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/DZJN 46-2021
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Communication equipment
ICS Name: Comprehensive Application of Information Technology
Publish Date: 2021-09-26
Implement Date: 2021-11-01

Scope

Main Technical Content: 5.1 General Provisions 5.1.1 Color Management for Data Center Infrastructure According to the classification of infrastructure systems, the color marking of infrastructure should comply with the relevant provisions of the *GB/T 26261-2001 Paint Film Color Standard Samples*. 5.1.2 This document should follow the principles of visual aesthetics, color differentiation, economic feasibility, and ease of construction and maintenance. 5.1.3 For equipment, pipelines, and cables not mentioned in this document, it is recommended to refer to this document and adopt or add colors that do not conflict with this document for management. 5.1.4 The content of this document focuses on "color management", and text and symbolic markings should comply with relevant industry standards. 5.1.5 The implementation process of color management should adopt methods such as customized surface spraying and material wrapping. For renovation and expansion projects, color labels can be used. 5.1.6 The implementation of color management should meet the needs of intelligent operation and maintenance scenarios. 5.2 Color Management for Power Supply Systems 5.2.1 When the power supply system adopts a dual-path power supply architecture, color management should distinguish between the A and B path systems. 5.2.2 When a non-dual path power supply architecture is used, it is recommended to manage according to the A and B path systems specified in this document and colors that do not conflict with this document. 5.2.3 The A path of the power supply system should be brown, corresponding to YR05 in the *GB/T 26261-2001 Paint Film Color Standard Samples*. 5.2.4 The B path of the power supply system should be peacock blue, corresponding to PB11 in the *GB/T 26261-2001 Paint Film Color Standard Samples*. 5.3 Color Management for Air Conditioning Systems 5.3.1 Color should be matched according to the relative temperature of the supply and return water pipe

Development Information

Related Standards

Contact Us