T/SCDA 040-2020 Abolished Group standards

T/SCDA 040-2020 QN floor insulation and sound insulation system construction

T/SCDA 040-2020 QN floor insulation and sound insulation system construction

Publish Date: 2020-05-12 Implement Date: 2020-05-13 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/SCDA 040-2020
Standard Type: Group standards
Standard Status: Abolished
is_force_gb: no
CCS Name: Power transmission and transformation equipment
ICS Name: Comprehensive Building Materials
Publish Date: 2020-05-12
Implement Date: 2020-05-13

Scope

Main technical content: - The weighted impact sound improvement value of the QN floorboard soundproofing and thermal insulation system, ΔLW, dB≥15 - The design calculation value of the thermal conductivity of the QN soundproofing and thermal insulation board, W/(m·K) = 0.12×1.2 = 0.14 - The design calculation value of the thermal conductivity of the QN lightweight aggregate concrete, W/(m·K) = 0.28×1.3 = 0.36 - The impact sound improvement value of the QN 8mm-12mm soundproofing filler and 40mm lightweight aggregate concrete, ΔLW≥15dB

Development Information

Related Standards

Contact Us