T/LWB 002-2019 Active Group standards

T/LWB 002-2019 The rated voltage is 300/500 V and below for geothermal cables and wires

T/LWB 002-2019 The rated voltage is 300/500 V and below for geothermal cables and wires

Publish Date: 2019-08-01 Implement Date: 2019-08-20 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/LWB 002-2019
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Cables and their accessories
ICS Name: Comprehensive overview of wires and cables
Publish Date: 2019-08-01
Implement Date: 2019-08-20

Scope

Main technical content: 7.2 Conductors The conductors shall consist of one or more pure metal or metal alloy wires. If the conductors are composed of pure copper wires coated with a metal layer, the metal coating shall match the operating temperature of the conductors. The resistance of the conductors at (20 ± 1) °C shall comply with the company's process requirements, with a maximum deviation of +10% to 5%. 7.3 Insulation The insulation uses fluoroplastic, with a minimum average thickness of 0.3 mm, and the thinnest point shall not be less than 0.20 mm. The performance of the insulation material shall comply with the requirements of Table 1. 7.4 Shielding layer 7.4.1 The resistance shall comply with the requirements of GB/T 20841. 7.4.2 The penetration resistance of the shielding shall comply with the requirements of GB/T 20841.

Development Information

Related Standards

Contact Us