GB/T 19212.1-2023 Active National standards

GB/T 19212.1-2023 Safety of transformers,reactors,power supply units and combinations thereof—Part 1:General requirements and tests

GB/T 19212.1-2023 Safety of transformers,reactors,power supply units and combinations thereof—Part 1:General requirements and tests

Publish Date: 2023-09-07 Implement Date: 2024-04-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 273
Download

Basic Information

Standard Code: GB/T 19212.1-2023
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Transformer
ICS Name: Transformers, reactors, and inductors
Publish Date: 2023-09-07
Implement Date: 2024-04-01
Pages: 143 pages

Scope

This document specifies the electrical, temperature, and mechanical safety requirements for transformers, reactors, power supply devices, and their combinations.
This document applies to the following independent and supporting stationary or mobile dry-type transformers, power supply devices (including switching power supplies), reactors, and their combinations in the safety field. Their windings may be encapsulated or non-encapsulated, and they do not form part of the distribution network.
Note 1: The differences between transformers, power supply devices, and switching power supply devices are as follows:
——For transformers, there is no change in frequency. However, transformers (such as constant-voltage transformers) may have an internal resonance frequency of no more than 30 kHz;
——For power supply devices, the internal operating frequency and waveform are different from the frequency and waveform of the power supply, and the internal operating frequency does not exceed 500 Hz (see Definition 3.1.17);
——For switching power supply devices, the internal operating frequency and waveform are different from the frequency and waveform of the power supply, and the internal operating frequency exceeds 500 Hz but does not exceed 100 MHz.
Other parts of GB/T19212 can be found in the introduction of this document.
a) Stationary or mobile, single-phase or multi-phase, air-cooled (self-cooling or air-cooling), independent or supporting isolation transformers and safety isolation transformers, which have the following characteristics:
1) The rated power supply voltage does not exceed AC 1000 V;
2) The rated power supply frequency does not exceed 500 Hz.

Development Information

Word Count: 279 Thousand words Pages: 143 pages

Replace the following standards

Adopt standards

IEC 61558-1:2017

Related Standards