T/CEEIA 785-2024 Active Group standards

T/CEEIA 785-2024 Low-voltage photovoltaic system arc fault detector (PV-AFD)

T/CEEIA 785-2024 Low-voltage photovoltaic system arc fault detector (PV-AFD)

Publish Date: 2024-03-31 Implement Date: 2024-03-31 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/CEEIA 785-2024
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: -
ICS Name: Fuses and other overload protection devices
Publish Date: 2024-03-31
Implement Date: 2024-03-31

Scope

Scope: This document specifies the terms, definitions, classification, characteristics, marking, standard working conditions, structure, operation requirements, and testing of arc fault detectors (PV-AFD) for low-voltage photovoltaic (PV) systems. The PV-AFD specified in this document is applicable to the detection of DC arc faults in PV systems with a maximum open-circuit voltage not exceeding 1500 V DC. Note 1: According to GB/T 16895.32, the PV-AFD specified in this document is used for monitoring series arc faults caused by insulation failures in PV systems, and issues a signal output when a sustained arc in the PV system is sufficient to ignite other flammable materials. Note 2: The PV-AFD specified in this document can be installed as a standalone device in PV junction boxes or as an electrical accessory in PV inverters and other equipment for arc fault monitoring in PV systems. Main technical content: This document specifies the terms, definitions, classification, characteristics, marking, standard working conditions, structure, operation requirements, and testing of arc fault detectors (PV-AFD) for low-voltage photovoltaic (PV) systems. The PV-AFD specified in this document is applicable to the detection of DC arc faults in PV systems with a maximum open-circuit voltage not exceeding 1500 V DC. Note 1: According to GB/T 16895.32, the PV-AFD specified in this document is used for monitoring series arc faults caused by insulation failures in PV systems, and issues a signal output when a sustained arc in the PV system is sufficient to ignite other flammable materials. Note 2: The PV-AFD specified in this document can be installed as a standalone device in PV junction boxes or as an electrical accessory in PV inverters and other equipment for arc fault monitoring in PV systems.

Development Information

Related Standards

Contact Us