T/CES 070-2021 Active Group standards

T/CES 070-2021 Module-based high-frequency isolation boosting converter for photovoltaic DC-to-AC converter technical specification

T/CES 070-2021 Module-based high-frequency isolation boosting converter for photovoltaic DC-to-AC converter technical specification

Publish Date: 2021-09-28 Implement Date: 2021-09-30 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/CES 070-2021
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Electrician
ICS Name: Comprehensive Electrical Engineering
Publish Date: 2021-09-28
Implement Date: 2021-09-30

Scope

Scope: This document specifies the technical requirements, test methods, and inspection rules for modular high-frequency isolation step-up photovoltaic DC converters (hereinafter referred to as "converters"). This document applies to newly manufactured converters that meet the following conditions: a) The maximum open-circuit voltage of the photovoltaic string connected to the junction box is less than or equal to 1,500V; b) The DC output voltage is greater than or equal to ±3kV and less than or equal to ±35kV; c) The operating frequency is greater than or equal to 1kHz, and the voltage conversion and electrical isolation are achieved by an isolation transformer; d) Energy flows unidirectionally from the photovoltaic array to the DC distribution network. Main technical content: This document specifies the technical requirements, test methods, and inspection rules for modular high-frequency isolation step-up photovoltaic DC converters (hereinafter referred to as "converters"). This document applies to newly manufactured converters that meet the following conditions: a) The maximum open-circuit voltage of the photovoltaic string connected to the junction box is less than or equal to 1,500V; b) The DC output voltage is greater than or equal to ±3kV and less than or equal to ±35kV; c) The operating frequency is greater than or equal to 1kHz, and the voltage conversion and electrical isolation are achieved by an isolation transformer; d) Energy flows unidirectionally from the photovoltaic array to the DC distribution network. (1) Terminology The term and definitions in the "Technical Specifications for Modular High-Frequency Isolation Step-Up Photovoltaic DC Converters" inherit the terminology and definitions in national and industry standards. This document mainly refers to NB/T 32004—2018, GB/T 19826—2014, GB/T 13498—2017, and GB/T 34139—2017. The following terms and definitions apply to this document. (2) Technical requirements The techni

Development Information

Related Standards

Contact Us