GB/T 19216.2-2021 Active National standards

GB/T 19216.2-2021 Circuit integrity test for electric cables or optical fiber cables under fire conditions—Part 2:Test method for fire with shock at a temperature of at least 830 ℃ for cables of rated voltage up to and including 0.6/1 kV and with an overall diameter not exceeding 20 mm

GB/T 19216.2-2021 Circuit integrity test for electric cables or optical fiber cables under fire conditions—Part 2:Test method for fire with shock at a temperature of at least 830 ℃ for cables of rated voltage up to and including 0.6/1 kV and with an overall diameter not exceeding 20 mm

Publish Date: 2021-05-21 Implement Date: 2021-12-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 19216.2-2021
Standard Type: National standards
Standard Status: Active
is_force_gb: no
CCS Name: Cables and their accessories
ICS Name: Cable
Publish Date: 2021-05-21
Implement Date: 2021-12-01
Pages: 20 pages

Scope

This document describes the test method for fire-resistant cables to maintain line integrity when subjected to flames and impact vibration under specified conditions. This document is applicable to cables with a rated voltage of 0.6/1 kV and below, including metal conductor data with a rated voltage below 80 V, as well as telecommunications cables and optical cables. This document is applicable to test cables with an outer diameter of less than or equal to 20 mm. Cables with larger diameters will be tested using the equipment, procedures, and requirements of GB/T 19216.1. This document describes the test failure points, continuity inspection devices, test samples, test procedures, and test reports for rated voltage 0.6/1 kV and below power cables and control cables in detail. The test failure points, continuity inspection devices, test samples, test procedures, and test reports for metal conductor data and telecommunications cables and optical cables are not provided. Although the scope of application is limited to cables with a rated voltage of 0.6/1 kV and below, it can also be applied to cables with a rated voltage of 1.8/3(3.3) kV and below when the manufacturer and buyer agree and are equipped with suitable fuses. Appendix A provides a verification method for the test burner and control system. When identifying markings is necessary, markings can be selected on the cables to indicate compliance with this document. Warning: The tests in this document may involve the use of dangerous voltages and temperatures. Appropriate precautions should be taken to prevent potential risks of electric shock, combustion, fire, and explosion, as well as any harmful gases that may be generated.

Development Information

Word Count: 40 Thousand words Pages: 20 pages

Same series standard

Referenced Standards

IEC 60269-3 IEC 60584-1

Adopt standards

IEC 60331-2:2018