T/ZZAS 017-2022 Active Group standards

T/ZZAS 017-2022 Intelligent sensor zone-type vibration optical fiber intrusion detector

T/ZZAS 017-2022 Intelligent sensor zone-type vibration optical fiber intrusion detector

Publish Date: 2022-11-30 Implement Date: 2022-12-06 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/ZZAS 017-2022
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: -
ICS Name: Alarm and warning systems
Publish Date: 2022-11-30
Implement Date: 2022-12-06

Scope

Main technical content: 5. Technical requirements 5.1 Structural and appearance requirements — The surface of the equipment shall not have obvious dents, scratches, cracks, deformation, or contamination. The surface coating layer should be uniform, free from bubbles, cracking, peeling, abrasion, or other mechanical damage. Metal parts should not have rust or mechanical damage. — The connection between the fiber optic vibration sensor and the signal processor should be secure and free from looseness. — All operating switches and buttons should be flexible, reliable, and convenient to use. Switches selected for user use should be easy to operate. — The text, symbols, and logos describing the functions should be correct, clear, and well-formatted. All relevant texts must be in Chinese, with optional support for other languages. — The display or indicator lights should be clear. 5.2 Functional requirements — The protection level of the housing for indoor and outdoor equipment shall meet the requirements specified in GB/T 4208-2017, with an IP21 rating for indoor equipment and an IP56 rating for outdoor equipment. 5.3 Performance requirements — The alarm function should trigger an alarm state when the acceleration value specified in Table 1 of GB/T 10408.8-2008 is exceeded, with an alarm signal duration of at least 1 second. — The intrusion alarm indication function should accurately indicate the location of the event when the system is triggered. When multiple locations of the same fiber optic vibration sensor are triggered simultaneously, none of the locations should be missed. — The fiber break alarm function should generate a fiber break alarm signal when the optical signal attenuation exceeds the set value or the optical path is damaged, and the location of the fiber break should be indicated. The output format of this signal should be specified in the user manual and should be distinguishable from other alarm signals. — The maximum detec

Development Information

Related Standards

Contact Us