T/GZPX 3-2025 Bottled Liquefied Petroleum Gas Emergency Shut-off Valve
T/GZPX 3-2025 Bottled Liquefied Petroleum Gas Emergency Shut-off Valve
Basic Information
Scope
Scope: This document is applicable to emergency shut-off valves for bottled liquefied petroleum gas installed on the outlet of the angle valve of the steel cylinder for bottled liquefied petroleum gas, with an inlet pressure of 0.03 to 1.56 MPa and an operating temperature of -45 to +60℃. All pressure values mentioned in this standard, unless otherwise specified, refer to gauge pressure. Main technical content: This document specifies the general requirements for emergency shut-off valves for bottled liquefied petroleum gas (hereinafter referred to as shut-off valves), including materials and structure, technical requirements, test methods, inspection rules, marking and user's manual, packaging, transportation and storage, installation, use, and daily maintenance.