GB/T 4011-1983
Replaced
GB/T 12527-2008
Active
National standards
GB/T 12527-2008 Aerial insulated cables for rated voltages up to and including 1 kV
GB/T 12527-2008 Aerial insulated cables for rated voltages up to and including 1 kV
Basic Information
Standard Code:
GB/T 12527-2008
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Cables and their accessories
ICS Name:
Cable
Publish Date:
2008-06-30
Implement Date:
2009-04-01
Pages:
15 pages
Scope
This standard specifies the technical requirements, test methods, acceptance rules, packaging, transportation, and storage for overhead insulated cables with a rated voltage of 1 kV or less in AC systems. This standard applies to overhead power cables with a rated voltage of U ≤ 1 kV, which are used in AC power lines and are made of copper cores, aluminum cores, aluminum alloy cores, and weather-resistant PVC, polyethylene, and cross-linked polyethylene insulation.
Development Information
Replace the following standards
Related Standards
GB/T 4012-1983
Replaced
GB/T 4012-1983 2.6/9.5mm composite coaxial cable for telecommunication use
GB/T 5441.10-1985
Replaced
GB/T 5441.10-1985 Test methods for communication cable—Measurement of actual length of coaxial pair—Sine wave method
GB/T 5441.1-1985
Replaced
GB/T 5441.1-1985 Test methods for communication cable General
GB/T 5441.2-1985
Replaced
GB/T 5441.2-1985 Test methods for communication cable Capacitance test Bridge method
GB/T 5441.3-1985
Replaced