T/CI 056-2023 Active Group standards

T/CI 056-2023 LED Energy-Storage Road Lamp (LED ERS)

T/CI 056-2023 LED Energy-Storage Road Lamp (LED ERS)

Publish Date: 2023-04-26 Implement Date: 2023-04-26 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/CI 056-2023
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Electric light source products
ICS Name: Lighting equipment
Publish Date: 2023-04-26
Implement Date: 2023-04-26

Scope

Scope: This document specifies the basic requirements, technical requirements, test methods, inspection rules, labels, packaging, transportation, and storage for LED energy storage road lamps (referred to as "lamps"). This document applies to LED energy storage lamps and applications used for road lighting; Main technical content: 5. Technical requirements - The surface of the lamp should be smooth, with a uniform color coating without defects such as drip, piling, or exposed substrate that affect appearance. - There should be no sharp corners or burrs inside or outside the lamp body that pose a safety risk, and fasteners should be firmly connected. 5.2.1 Charging voltage control Under normal operating conditions and fault conditions, the charging voltage should not cause overcharging of the battery or battery pack. 5.2.2 Charging current control Under normal operating conditions and fault conditions, the charging current should not cause overcurrent charging of the battery or battery pack. 5.2.3 Discharging current control Under normal operating conditions and fault conditions, the discharging current should not cause overcurrent discharging of the battery or battery pack. 5.2.4 Charge-discharge temperature control When the temperature exceeds 60°C, the battery should not be able to charge or discharge. When the charging or discharging behavior stops, the temperature value should not exceed 60°C. 5.3 Battery protection 5.3.1 Overvoltage charging protection During overvoltage charging, the charging current is 1C, and the charging voltage is (n×3.6)V. After the test, the battery protection device should start protection and not explode, catch fire, or leak fluid. 5.3.2 Overcurrent charging protection During overcurrent charging, the charging current is 1.5 times the overcurrent charging protection current. After the test, the battery protection device should start protection and not explode, catch fire, or leak fluid. 5.3.3 U

Development Information

Related Standards

Contact Us