T/CES 248-2023 Active Group standards

T/CES 248-2023 Technical requirements for integrating prefabricated container-type lithium battery energy storage systems into direct current distribution networks

T/CES 248-2023 Technical requirements for integrating prefabricated container-type lithium battery energy storage systems into direct current distribution networks

Publish Date: 2023-12-27 Implement Date: 2023-12-28 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/CES 248-2023
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Electrician
ICS Name: The comprehensive overview of batteries and storage batteries
Publish Date: 2023-12-27
Implement Date: 2023-12-28

Scope

Scope: This standard specifies the principles and technical requirements that should be followed when prefabricated cabin-type lithium battery energy storage systems are connected to DC power grids, including power quality, power control, grid adaptability, protection and safety automatic devices, communication and automation, power metering, external interfaces, and grid connection testing. This standard applies to prefabricated cabin-type lithium battery energy storage systems with a rated power of 44MW or less that are connected to DC power grids with a nominal voltage of ±35kV or lower. Prefabricated cabin-type lithium battery energy storage systems of other power ratings and voltage levels may refer to this standard for implementation. Main technical content: This standard specifies the principles and technical requirements that should be followed when prefabricated cabin-type lithium battery energy storage systems are connected to DC power grids, including power quality, power control, grid adaptability, protection and safety automatic devices, communication and automation, power metering, external interfaces, and grid connection testing. (1) Terms and definitions include the definitions of prefabricated cabin-type lithium battery energy storage systems, DC power grids, DC voltage imbalance, DC voltage ripple factor, and DC voltage sags. (2) General principles specify the principles that should be followed when prefabricated cabin-type lithium battery energy storage systems are connected to DC power grids. (3) Connection conditions specify the technical requirements for voltage matching, power quality, power control, voltage regulation fault ride-through, protection and safety automatic devices, communication and automation, power metering, and external interfaces. (4) Connection tests specify the technical requirements for power quality tests, power control tests, grid adaptability tests, charge/discharge time tests, grid-interactive protection fu

Development Information

Related Standards

Contact Us