PDF

GB/T 20833.1-2016

GB/T 20833.1-2016 Rotating electrical machines—the stator winding insulation of rotating electrical machines—Part 1:Off-line partial discharge measurements

Available format(s)
PDF
Language(s)
Chinese
Publish Date
2016-02-24

Abstract

This part of GB/T 20833 specifies the general basic specifications for off-line partial discharge measurement of the stator winding insulation of rotating motors (referred to as motors) when tested with an AC voltage of up to 400 Hz, including:
—— Measurement methods and instruments;
—— Arrangement of the test circuit;
—— Standardization of the test procedures;
—— Reduction of noise;
—— Preparation of test result documents;
—— Evaluation of test results.
This part is applicable to motors with anti-corona-treated slots or molded coils. This part is generally effective for motors with a rated voltage of 6 kV or higher. The measurement methods described in this part can also be applied to motors without anti-corona-treated slots, but the measurement results may vary, which is beyond the scope of this part.

General Product Information

Document Type National standards
Standard Status Replaced
Standard Code GB/T 20833.1-2016
CCS Rotating motor
ICS Rotating motor comprehensive
Implement Date 2016-09-01
Price $ 107
Subtotal $ 107
Tax $ 0.00