T/CCGA 20016-2024 Liquid Helium Tank Container Safety Use Technical Specification
T/CCGA 20016-2024 Liquid Helium Tank Container Safety Use Technical Specification
Basic Information
Scope
Main technical content: This document specifies the relevant terms, basic design and manufacturing requirements, transportation and storage, use and maintenance, operation and protection, and emergency response for liquid helium tank containers (hereinafter referred to as liquid helium tank containers). This document is applicable to standard tank containers used for loading liquid helium and operating at normal ambient temperatures, with a design pressure of not less than 0.5MPa, a geometric volume of not less than 10 cubic meters, and employing different cold shield structures and high-vacuum multi-layer insulation methods. The requirements set forth in this document are basic safety technical requirements. Liquid helium tank containers that comply with this document can be used for road and waterway transportation, as well as combined transport involving these modes of transportation.