T/GXAS 492-2023 Active Group standards

T/GXAS 492-2023 Determination of water quality using high-performance liquid chromatography-tandem mass spectrometry for the determination of two types of lincosamide and four types of macrolide antibiotics

T/GXAS 492-2023 Determination of water quality using high-performance liquid chromatography-tandem mass spectrometry for the determination of two types of lincosamide and four types of macrolide antibiotics

Publish Date: 2023-05-18 Implement Date: 2023-05-24 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Out of stock

Basic Information

Standard Code: T/GXAS 492-2023
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Environmental protection
ICS Name: \nChemical testing of water
Publish Date: 2023-05-18
Implement Date: 2023-05-24

Scope

Scope: This document describes the method of determining two lincomycin antibiotics and four macrolide antibiotics in water using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). This document is applicable to the determination of lincomycin, clindamycin, oleandomycin, tylosin, leucomycin A5, and josamycin (a total of two lincomycin antibiotics and four macrolide antibiotics) in surface water and domestic wastewater. Other lincomycin and macrolide compounds can be measured after suitability verification. When the injection volume is 5.0 μL, the detection limit of the direct injection method is 1.1 μg/L to 1.6 μg/L, and the lower limit of determination is 4.4 μg/L to 6.4 μg/L. When the enriched sample volume is 200 mL, the concentrated and diluted volume is 1.0 mL, and the injection volume is 5.0 μL, the detection limit of the solid-phase extraction method is 2.4 ng/L to 9.7 ng/L, and the lower limit of determination is 9.6 ng/L to 38.8 ng/L. For details, please refer to Appendix A. Main technical content: This document describes the method of determining two lincomycin antibiotics and four macrolide antibiotics in water using HPLC-MS/MS. This document is applicable to the determination of lincomycin, clindamycin, oleandomycin, tylosin, leucomycin A5, and josamycin (a total of two lincomycin antibiotics and four macrolide antibiotics) in surface water and domestic wastewater. Other lincomycin and macrolide compounds can be measured after suitability verification. When the injection volume is 5.0 μL, the detection limit of the direct injection method is 1.1 μg/L to 1.6 μg/L, and the lower limit of determination is 4.4 μg/L to 6.4 μg/L. When the enriched sample volume is 200 mL, the concentrated and diluted volume is 1.0 mL, and the injection volume is 5.0 μL, the detection limit of the solid-phase extraction method is 2.4 ng/L to 9.7 ng/L, and the lower limit of determination is 9.6 ng/L to 38.8 ng/L. For details, please refer to A

Development Information

Related Standards

Contact Us