T/CECA-G 0209-2022 The methods for testing and calculating the energy efficiency of home and similar purpose heating equipment
T/CECA-G 0209-2022 The methods for testing and calculating the energy efficiency of home and similar purpose heating equipment
Basic Information
Scope
This document specifies the test methods and energy efficiency calculation for heating equipment for household and similar purposes (hereinafter referred to as "heating equipment"). This document is applicable to heating equipment that uses water as the heating medium and has a maximum heating working water pressure of no more than 0.6 MPa, including: a) constant-pressure electric water boilers with a rated power of no more than 18 kW and a rated outlet water temperature of no more than 85℃ (hereinafter referred to as "electric boilers"); b) gas heating water boilers with a rated heat load of less than 100 kW and a working water temperature of no more than 95℃ (hereinafter referred to as "gas heating boilers"); c) air-source heat pumps with a nominal heating capacity of no more than 35 kW and a working water temperature of no more than 60℃. This document is not applicable to solar heating equipment.