DB37/T 2368-2022 Active

DB37/T 2368-2022

This document is applicable to the detection of the compressive strength of structural concrete using the core drilling method. When there are many components to be tested, the rebound method, the ultrasonic rebound comprehensive method, the post-installation pull-out method, etc. are used in combination with the core drilling method to form the core drilling correction method. The results of the core drilling method are used to correct the results obtained by other detection methods, making the detection results more reliable and reducing the damage to the structure.

Publish Date: 2022-11-24

DB37/T 2367-2022 Active

DB37/T 2367-2022 "Technical Specification for Testing the Compressive Strength of Mortar Using Rebound Method"

This document is applicable to the testing of the compressive strength of masonry mortar using the rebound method.

Publish Date: 2022-11-24

DB37/T 2364-2022 Active

DB37/T 2364-2022 "Post-anchor method for testing the compressive strength of concrete technical specification"

This document is applicable to the detection of the compressive strength of structural concrete using the post-anchoring method.

Publish Date: 2022-11-24

DB37/T 2363-2022 Active

DB37/T 2363-2022

This document is applicable to the detection of the compressive strength of masonry mortar using the penetration method.

Publish Date: 2022-11-24

DB37/T 2369-2022 Active

DB37/T 2369-2022

This document is applicable to the testing of the compressive strength of masonry mortar using the local compression method with mortar pieces.

Publish Date: 2022-11-24

DB37/T 2371-2022 Active

DB37/T 2371-2022 "Technical specification for testing the shear strength of masonry using core drilling and measuring the strength of mortar"

This document is applicable to the testing of the shear strength of masonry with a thickness of 240 mm and the compressive strength of masonry mortar. The masonry materials include sintered ordinary bricks, sintered porous bricks, concrete ordinary bricks, concrete porous bricks, or autoclaved fly ash bricks. The dimensions of the masonry blocks are 240 mm × 115 mm × 53 mm or 240 mm × 115 mm × 90 mm.

Publish Date: 2022-11-24

DB37/T 2361-2022 Active

DB37/T 2361-2022

This document is applicable to the detection of the compressive strength of ordinary concrete in normal use conditions using the ultrasonic rebound method. It is not applicable to the detection of the compressive strength of concrete that has been damaged due to frost damage, chemical erosion, fire, high temperature, etc., resulting in surface loosening and peeling.

Publish Date: 2022-11-24

DB37/T 5237-2022 Active

DB37/T 5237-2022 "Ultra Low Energy Public Building Technology Standards"

This document is applicable to the design, construction, inspection, acceptance, operation management, and evaluation of ultra-low energy consumption public buildings in Shandong Province.

Publish Date: 2022-11-24

DB37/T 5047-2022 Active

DB37/T 5047-2022 "Low Temperature Hot Water Ground Source Heat Pump Radiant Floor Heating Engineering Technical Specification"

This regulation applies to ground radiant heating projects in industrial and civil buildings that use hot water as the heat medium.

Publish Date: 2022-11-24

DB37/ 5026-2022 Active

DB37/ 5026-2022 "Energy-saving design standards for residential buildings"

This standard applies to the energy-saving design of new, expanded, and renovated residential buildings, such as dwellings and collective dormitories.

Publish Date: 2022-11-24

DB3709/T 019-2022 Active

DB3709/T 019-2022 Clean and Honest Village Construction Standards

Publish Date: 2022-11-18

DB37/T 4555-2022 Active

DB37/T 4555-2022 Guidelines for the establishment of a commerce and trade circulation supply chain system

Publish Date: 2022-11-15