GB/T 1920-1980
Abolished
HY/T 240.3-2018
Active
Industry standards-The ocean
HY/T 240.3-2018 Code for design of recirculating cooling seawater system—Part 3:Requirement of seawater pre-treatment
HY/T 240.3-2018 Code for design of recirculating cooling seawater system—Part 3:Requirement of seawater pre-treatment
Basic Information
Standard Code:
HY/T 240.3-2018
Standard Type:
Industry standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Oceanography
ICS Name:
Geology, meteorology, and hydrology
Publish Date:
2018-06-13
Implement Date:
2018-09-03
Pages:
13 pages
Scope
This section specifies the technical requirements for the design of seawater pre-treatment for seawater circulation cooling systems.
This section applies to the design of seawater pre-treatment for newly built, modified, or expanded seawater circulation cooling systems. The design of seawater pre-treatment for other seawater utilization systems can be implemented with reference to this section.
Development Information
Referenced Standards
GB 50013-2006
JTJ 275
GB 4482-1993 Water clarifying agent—Ferric chloride
GB/T 4482-2006 Water treatment chemicals—Ferric chloride
GB/T 4482-2018 Water treatment chemicals—Ferric chloride
GB/T 12763.4-1991 The specification for oceanographic survey observations of chemical parameters in sea water
GB/T 12763.4-2007 Specifications for oceanographic survey—Part 4:Survey of chemical parameters in sea water
GB 14591-1993 Water clarifying agent—Polymeric ferric sulfate
GB 14591-2006 Water treatment chemicals—Poly ferric sulfate
GB/T 14591-2016 Water treatment chemicals—Poly ferric sulfate
GB 15892-2003 Water treatment chemical—Poly aluminium chloride
GB 15892-2009 Poly aluminium chloride for treatment of drinking water
GB 15892-2020 Polyaluminium chloride for treatment of drinking water
GB 17378.4-1998 The specification for marine monitoring Part 4:Seawater analysis
GB 17378.4-2007 The specification for marine monitoring—Part 4:Seawater analysis
GB 17514-1998 Water treatment chemicals—Polyacrylamide
GB/T 17514-2008 Water treatment chemicals—Polyacrylamide
GB/T 17514-2017 Water treatment chemicals—Anionic and non-ionic polyacrylamides
GB/T 33584.1-2017 Seawater quality requirements and analysis methods for seawater cooling system—Part 1:Determination of calcium and magnesium
GB/T 33584.4-2017 Seawater quality requirements and analysis methods for seawater cooling system—Part 4:Determination of sulfate
GB/T 33584.5-2017 Seawater quality requirements and analysis methods for seawater cooling system—Part 5:Determination of dissolved solid
GB/T 33584.6-2017 Seawater quality requirements and analysis methods for seawater cooling system—Part 6:Determination of heterotrophic bacteria
CJ/T 83-1999 Inclined tube settler for water clarification
CJ/T 83-2016 Inclined tube for water and wastewater treatment
HY/T 187.2-2015 Code for design of recirculating cooling seawater system—Part 2:Requirement of wastewater engineering
HY/T 191-2015 Determination of Iron for cooling seawater
HG 2227-1991 Water treatment agent: aluminum sulfate
CJJ 40-2011 Code for design of water supply engineering using high-turbidity raw water
Related Standards
GB/T 958-1989
Replaced
GB/T 958-1989 Geological symbols used for regional geological maps (1:50000)
GB/T 11615-1989
Replaced
GB/T 11615-1989 Geologic exploration standard of geothermal resources
GB/T 12329-1990
Active
GB/T 12329-1990 Karst geology terminology
GB/T 12745-1991
Replaced
GB/T 12745-1991 Static penetrometer
GB/T 12746-1991
Replaced