GB 6450-1986
Replaced
GB/T 6451-2008
Replaced
National standards
GB/T 6451-2008 Specification and technical requirements for oil-immersed power transformers
GB/T 6451-2008 Specification and technical requirements for oil-immersed power transformers
Basic Information
Standard Code:
GB/T 6451-2008
Standard Type:
National standards
Standard Status:
Replaced
is_force_gb:
no
CCS Name:
Transformer
ICS Name:
Transformers, reactors, and inductors
Publish Date:
2008-01-22
Implement Date:
2008-09-01
Pages:
48 pages
Scope
This standard specifies the performance parameters, technical requirements, test items, and markings, lifting, installation, transportation, and storage of three-phase and single-phase oil-immersed power transformers with a rated capacity of 30kVA and above, and voltage levels of 6kV, 10kV, 20kV, 35kV, 66kV, 110kV, 220kV, 330kV, and 500kV. This standard applies to oil-immersed power transformers with voltage levels of 6kV to 500kV, a rated capacity of 30kVA and above, and a rated frequency of 50 Hz.
Development Information
Replace the following standards
Superseded by the following standards
Referenced Standards
GB/T 2900.15-1997 Electrotechnical terminology Transformer, instrument transformer, voltage regulator and reactor
GB 1094.1-1996 Power transformers—Part 1:General
GB/T 1094.1-2013 Power transformers—Part 1:General
GB 1094.2-1996 Power transformers—Part 2:Temperature rise
GB/T 1094.2-2013 Power transformers—Part 2:Temperature rise for liquid-immersed transformers
GB/T 1094.3-2003 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB/T 1094.3-2017 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
GB 1094.5-2003 Power transformers—Part 5:Ability to withstand short circuit
GB/T 1094.5-2008 Power transformers—Part 5:Ability to withstand short circuit
GB/T 15164-1994 Loading guide for oil-immersed power transformers
JB/T 10088-2004
Related Standards
GB/T 7449-1987
Replaced
GB/T 7449-1987 Guide to the lightning impulse and switching impulse testing of power transformers and reactors
GB 13028-1991
Abolished
GB 13028-1991 Isolating transformers and safety isolating transformers Requirements
GB/T 14006-1992
Active
GB/T 14006-1992 Outline dimensions of transformers and inductors for use in telecommunication and electronic equipment—Part 1:Transformers and inductors using YEI-1 laminations
GB/T 14860-1993
Replaced
GB/T 14860-1993 Generic specification for transformers and inductors for use in telecommunication and electronic equipment
GB/T 15164-1994
Replaced