GB 8662-1988
Replaced
YY 1116-2010
Replaced
Industry standards-Medicine
YY 1116-2010 Absorbable surgical suture
YY 1116-2010 Absorbable surgical suture
Basic Information
Standard Code:
YY 1116-2010
Standard Type:
Industry standards
Standard Status:
Replaced
is_force_gb:
no
CCS Name:
Medical hygiene products
ICS Name:
Surgical instruments and materials
Publish Date:
2010-12-27
Implement Date:
2012-06-01
Pages:
18 pages
Scope
This standard specifies the classification, requirements, test methods, inspection rules, marking, user manuals, packaging, transportation, and storage requirements for absorbable surgical sutures.
This standard applies to absorbable surgical sutures (hereinafter referred to as sutures). Sutures are used by medical institutions for suturing and ligating human tissues during surgical procedures.
Development Information
Replace the following standards
Superseded by the following standards
Referenced Standards
GB/T 6682-2008 Water for analytical laboratory use—Specification and test methods
GB/T 9737-2008 Chemical reagent—General rules for the determination of readily carbonizable substances
GB/T 9969-2008 General principles for preparation of instructions for use of industrial products
GB/T 14233.1-2008 Test methods for infusion,transfusion,injection equipments for medical use—Part 1:Chemical analysis methods
GB/T 14436-1993 General principles of industrial product guarantee documents
GB/T 16175-2008 Biological evaluation test methods for medical organic silicon materials
GB/T 16886.3-2008 Biological evaluation of medical devices—Part 3:Tests for genotoxicity,carcinogenicity and reproductive toxicity
GB/T 16886.4-2003 Biological evaluation of medical devices—Part 4:Selection of tests for interactions with blood
GB/T 16886.5-2003 Biological evaluation of medical devices—Part 5:Test for in vitro cytotoxicity
GB/T 16886.6-1997 Biological evaluation of medical devices—Part 6:Tests for local effects after implantation
GB/T 16886.10-2005 Biological evaluation of medical devices—Part 10:Tests for irritation and delayed-type hypersensitivity
GB/T 16886.11-1997 Biological evaluation of medical devices—Part 11:Tests for systemic toxicity
GB/T 16886.13-2001 Biological evaluation of medical devices—Part 13:Identification and quantification of degradation products from polymeric medical devices
YY 0043-2005 Medical suture needle
YY/T 0466.1-2009 Medical devices—Symbols to be used with medical device labels, labelling and information to be supplied—Part 1:General requirements
中华人民共和国药典 2010年版(二部)
Related Standards
GB 2766-1995
Replaced
GB 2766-1995 Haemostatic forceps with box joint—General specifications
GB/T 10160-1995
Abolished
GB/T 10160-1995 Test methods of locking force and opening force for medical use forceps
GB 9706.4-1999
Replaced
GB 9706.4-1999 Medical electrical equipment—Part 2:Particular requirements for the safety of high frequency surgical equipment
YY 0464-2003
Replaced
YY 0464-2003 Single use hemoperfutor
YY 0054-2003
Replaced