JG/T 255-2020 Active Industry standards-The construction industry

JG/T 255-2020 Sealed insulating glass unit with shading inside

JG/T 255-2020 Sealed insulating glass unit with shading inside

Publish Date: 2020-01-13 Implement Date: 2020-08-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 42
Download

Basic Information

Standard Code: JG/T 255-2020
Standard Type: Industry standards
Standard Status: Active
is_force_gb: no
CCS Name: Architectural glass
ICS Name: \nGlass
Publish Date: 2020-01-13
Implement Date: 2020-08-01
Pages: 18 pages

Scope

This standard specifies the terms and definitions, classification and marking, materials, accessories, and construction of built-in shading insulating glass products, as well as requirements, test methods, inspection rules, marking, labels, and accompanying documents, packaging, transportation, and storage. This standard applies to built-in shading insulating glass products used in buildings such as doors and windows, curtain walls, skylights, and partitions.

Development Information

Word Count: 34 Thousand words Pages: 18 pages

Replace the following standards

Referenced Standards

GB/T 191-2000 Packaging—Pictorial marking for handling of goods GB/T 191-2008 Packaging—Pictorial marking for handling of goods GB/T 191-2025 Graphical symbols marking for handling and storage of packages GB/T 2680-1994 Determination of light transmittance, solar direct transmittance, total solar energy transmittance and ultraviolet transmittance for glass in building and related glazing factors GB/T 2680-2021 Glass in building—Determination of light transmittance,solar direct transmittance,total solar energy transmittance,ultraviolet transmittance and related glazing factors GB 5237.1-2004 Wrought aluminium alloy extruded profiles for architecture—Part 1:Untreated profiles GB/T 5237.1-2008 Aluminium alloy extruded profiles for architecture—Part 1:Mill finish profiles GB/T 5237.1-2017 Aluminium alloy extruded profiles for architecture—Part 1:Mill finish profiles GB 5237.2-2004 Wrought aluminium alloy extruded profiles for architecture—Part 2:Anodized colored profiles GB/T 5237.2-2008 Wrought aluminium alloy extruded profiles for architecture—Part 2:Anodized profiles GB/T 5237.2-2017 Wrought aluminium alloy extruded profiles for architecture— Part 2:Anodized profiles GB 5237.3-2004 Wrought aluminium alloy extruded profiles for architecture—Part 3:Electrophoretic coating profiles GB/T 5237.3-2008 Wrought aluminium alloy extruded profiles for architecture—Part 3:Electrophoretic coating profiles GB/T 5237.3-2017 Wrought aluminium alloy extruded profiles for architecture—Part 3:Electrodeposition coating profiles GB 5237.4-2004 Wrought aluminium alloy extruded profiles for architecture—Part 4:Powder coating profiles GB/T 5237.4-2008 Wrought aluminium alloy extruded profiles for architecture—Part 4:Powder coating profiles GB/T 5237.4-2017 Wrought aluminium alloy extruded profiles for architecture—Part 4:Powder coating profiles GB 5237.5-2004 Wrought aluminium alloy extruded profiles for architecture—Part 5:PVDF coating profiles GB/T 5237.5-2008 Wrought aluminium alloy extruded profiles for architecture—Part 5:PVDF coating profiles GB/T 5237.5-2017 Wrought aluminium alloy extruded profiles for architecture— Part 5:Paint coating profiles GB 5237.6-2004 Wrought aluminium alloy extruded profiles for architecture—Part 6:Thermal barrier profiles GB/T 5237.6-2012 Wrought aluminium alloy extruded profiles for architecture—Part 6:Thermal barrier profiles GB/T 5237.6-2017 Wrought aluminium alloy extruded profiles for architecture—Part 6:Thermal barrier profiles GB/T 8484-2002 Graduation and test method for thermal insulating properties of windows GB/T 8484-2008 Graduation and test method for thermal insulating properties of doors and windows GB/T 8484-2020 Test method for thermal insulating performance for building exterior doors and windows GB/T 8814-1998 Unplasticized polyvinyl chloride (PVC) profiles for the frames of doors and windows GB/T 8814-2004 Unplasticized polyvinyl chloride(PVC-U)profiles for the doors and windows GB/T 8814-2017 Unplasticized polyvinyl chloride(PVC-U)profiles for the doors and windows GB/T 9969-2008 General principles for preparation of instructions for use of industrial products GB 9969.1-1998 General principles for preparation of instructions for use of industrial products GB/T 11944-2002 Sealed insulating glass unit GB/T 11944-2012 Insulating glass unit GB/T 11944-2025 Insulating glass unit GB/T 13560-2000 Materials for sintered neodymium iron boron permanent magnets GB/T 13560-2009 Materials for sintered neodymium iron boron permanent magnets GB/T 13560-2017 Sintered neodymium iron boron permanent magnets GB 15763.1-2001 Safety glazing materials in building Fire-resistant glass GB 15763.1-2009 Safety glazing materials in building—Part 1:Fire-resistant glass GB/T 15763.1-2025 Safety glazing materials in building—Part 1:Fire resistant glass GB/T 18915.2-2002 Coated glass—Part 2:low emissivity coated glass GB/T 18915.2-2013 Coated glass—Part 2:Low emissivity coated glass CB 867 JC/T 941-2016 Glazing fiber reinforced plastic extruded profiles for windows and doors JC/T 941-2004 Glazing fiber reinforced plastic extruded hollow profiles for windows and doors JC/T 1079-2020 JC/T 1079-2020 Vacuum Glass JC/T 1079-2008 JCT 1079-2008 Vacuum glass JC/T 2072-2011 The desiccant used in hollow glass JG/T 241-2009 Blinds and shutters—Mechanical endurance—Test methods JG/T 242-2009 Blinds and shutters—Measurement of operating force—Test methods JG/T 251-2009 Metal venetian blinds for shading of building JG/T 251-2017 Metal venetian blinds for shading of building JG/T 254-2009 Roller blind for building JG/T 254-2015 Roller blind for building JG/T 274-2010 General requirements for building shading product JG/T 274-2018 General technical requirements for blinds and shutters JG/T 278-2010 Motor for building shading product JG/T 399-2012 Terminology of solar shading product for building JG/T 440-2014 Test method for shading performance of windows and doors JG/T 455-2014 Tempered glass for window,door and curtain wall in buildings JG/T 499-2016 Nonmetal venetian blinds for shading of building JGJ 113-2009 Technical specification for application of architectural glass JGJ 113-2015 Technical specification for application of architectural glass JGJ/T 151-2008 Calculation specification for thermal performance of windows,doors and glass curtain-walls QB/T 2424 ISO 19467

Related Standards

Contact Us