GB/T 14598.301-2010
Replaced
GB/T 40091-2021
Active
National standards
GB/T 40091-2021 Requirements for safety measures of relaying protection and security automatic equipment in smart substation
GB/T 40091-2021 Requirements for safety measures of relaying protection and security automatic equipment in smart substation
Basic Information
Standard Code:
GB/T 40091-2021
Standard Type:
National standards
Standard Status:
Active
is_force_gb:
no
CCS Name:
Relay protection and automatic devices
ICS Name:
Other equipment related to the transmission and distribution networks
Publish Date:
2021-04-30
Implement Date:
2021-11-01
Publisher:
国家市场监督管理总局、国家标准化管理委员会
Technical Committee:
中国电力企业联合会
Pages:
13 pages
Scope
本标准规定了智能变电站继电保护和电网安全自动装置、相关二次设备及二次回路现场工作应遵循的总体要求、二次安全措施流程、二次安全措施制定要求、二次安全措施执行要求和二次安全措施恢复要求。本标准适用于智能变电站继电保护和电网安全自动装置、相关二次设备及二次回路的现场工作。
Development Information
Drafting Units:
国网湖南省电力有限公司电力科学研究院、国家电力调度控制中心、中国南方电网电力调度控制中心、国网浙江省电力有限公司电力科学研究院、国网江苏省电力有限公司电力科学研究院、国网湖南省电力有限公司邵阳供电分公司、国网湖南省电力有限公司检修公司、广东电网电力调度控制中心、国家电网有限公司华北分部、华北电力科学研究院有限责任公司、国网浙江省电力有限公司杭州供电公司、贵州电网有限责任公司电力科学研究院、国电南京自动化股份有限公司、南京南瑞继保电气有限公司
Drafting Persons:
梁文武、朱维钧、王中浪、黄佳胤、彭业、王松、高磊、王鹏飞、陈媛、方芳、宋爽、陈桥平、王增超、郑少明、刘苗、辛光明、侯伟宏、王宇、李玉平、陈建国
Referenced Standards
GB/T 20840.7-2007 Instrument transformers—Part 7:Electronic voltage transformers
GB/T 20840.8-2007 Instrument transformers—Part 8:Electronic current transformers
GB 26860-2011 Safety code of electric power industry—Electric part of power plants and transformer substations
DL/Z 860.1-2018 DL/Z 860.1-2018 Electric power automation communication networks and systems Part 1: General introduction
DL/Z 860.1-2004 Substation communication networks and systems - Part 1: General introduction
DL/T 860.4-2018 Electric power automation communication networks and systems - Part 4: Systems and project management
DL/T 860.6-2012 DL/T 860.6-2012 Electric Power Enterprise Automation Communication Network and System Part 6: Communication Configuration Description Language Related to Intelligent Electronic Devices in Substation
DL/T 860.10-2018 Part 10 of the guidelines for electric power automation communication networks and systems: Conformance testing
DL/T 860.10-2006 Substation communication networks and systems - Part 10: Conformance testing
DL/T 860.71-2014 Power automation communication networks and systems - Part 7-1: Basic communication architecture principles and models
DL/T 860.72-2013 Power automation communication networks and systems - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
DL/T 860.73-2013 Power automation communication networks and systems - Part 7-3: Basic communication structure for public data classes
DL/T 860.74-2014 Electric power automation communication networks and systems - Part 7-4: Basic communication structure compatible logical node classes and data classes
DL/T 860.81-2016 DL/T 860.81-2016 Electricity automation communication network and system Part 8-1: Specific communication service mapping (SCSM) - Mapping to MMS (ISO 9506-1 and ISO 9506-2) and ISO/IEC 8802-3
DL/T 860.91-2006 Substation communication networks and systems - Part 9-1: Mapping of specific communication services (SCSM) on a unidirectional multipoint point-to-point serial communication link for sampled values
DL/T 860.92-2016 Electric power automation communication networks and systems - Part 9-2: Specific communication service mapping (SCSM) - Sampling values based on ISO/IEC 8802-3
DL/T 860.801-2016 Electric power automation communication networks and systems - Part 80-1: Application guidelines for exchanging information based on CDC data model using DL/T 634.5101 or DL/T 634.5104 switching system
DL/T 860.901-2014 Power automation communication network and system Part 901: Application of DL/T 860 in inter-substation communication. (Note: English translation provided)
DL/T 860.904-2018 Power automation communication networks and systems - Part 90-4: Network engineering guidelines
DL/T 860.7410-2016 Power Automation Communication Networks and Systems Part 7-410: Basic Communication Architecture for Monitoring and Control of Hydropower Plants
DL/T 860.7420-2012 Electricity enterprise automation communication network and system Part 7-420: Basic communication structure Distributed energy logic nodes
DL/Z 860.7510-2016 Power Automation Communication Networks and Systems Part 7-510: Basic Communication Architecture, Hydropower Plant Modeling Principles and Application Guidelines
DL/T 995-2016 DL/T 995-2016 Inspection Regulations for Relay Protection and Automatic Equipment for Power Grid Safety
DL/Z 860.2-2006 Substation communication networks and systems - Part 2: Terminology
DL/T 860.4-2004 Substation communication networks and systems - Part 4: System and project management
DL/T 860.6-2008 Substation communication network and system - Part 6: Communication configuration description language related to intelligent electronic devices in substation
DL/T 860.71-2006 Substation communication networks and systems - Part 7-1: Basic communication architecture and models for substation and feeder equipment
DL/T 860.72-2004 Substation communication networks and systems - Part 7-2: Basic communication structure for substation and feeder equipment - Abstract communication service interface (ACSI)
DL/T 860.73-2004 Substation communication networks and systems - Part 7-3: Basic communication structure for substation and feeder equipment - Public data classes
DL/T 860.74-2006 Substation communication networks and systems - Part 7-4: Basic communication structure for substation and feeder equipment - Compatibility of logical node classes and data classes
DL/T 860.81-2006
DL/T 860.92-2006 Substation communication networks and systems - Part 9-2: Mapping of specific communication services mapping (SCSM) to ISO/IEC 8802-3 to sample values only
DL/T 995-2006 The inspection regulations for relay protection and automatic equipment for power grid security
DL/T 860.3-2004 Communication networks and systems in substations-Part 3:General requirements
Related Standards
GB/T 25093-2010
Active
GB/T 25093-2010 AC filters for HVDC systems
GB/T 25099-2010
Active
GB/T 25099-2010 Step-down power saving device on distribution networks
GB/T 25738-2010
Replaced
GB/T 25738-2010 Technical guideline of motor commissioning for nuclear power plant
GB/T 2694-2010
Replaced
GB/T 2694-2010 Specification of manufacturing for transmission line tower
GB/T 26217-2010
Replaced