GB/Z 22720.2-2013 Replaced National standards

GB/Z 22720.2-2013 Rotating electrical machines—Qualification and acceptance tests for partial discharge resistant electrical insulation systems(Type Ⅱ)used in rotating electrical machines fed from voltage converters

GB/Z 22720.2-2013 Rotating electrical machines—Qualification and acceptance tests for partial discharge resistant electrical insulation systems(Type Ⅱ)used in rotating electrical machines fed from voltage converters

Publish Date: 2013-12-17 Implement Date: 2014-05-10 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/Z 22720.2-2013
Standard Type: National standards
Standard Status: Replaced
is_force_gb: no
CCS Name: Rotating motor
ICS Name: Rotating motor comprehensive
Publish Date: 2013-12-17
Implement Date: 2014-05-10
Pages: 23 pages

Scope

This part of GB 22720 specifies the evaluation standards for the insulation structure of the stator/rotor windings of single-phase or multi-phase AC motors powered by pulse width modulation (PWM) inverters that generate repetitive impulse voltages and subjected to partial discharge during operation.
This part is applicable to the identification and approval tests of typical samples powered by voltage-type inverters.
This part is not applicable to:
——Rotating motors that only use inverters during startup;
——Traction electrical equipment and structures.

Development Information

Word Count: 40 Thousand words Pages: 23 pages

Superseded by the following standards

Referenced Standards

IEC 60034-18-1 IEC 60034-18-32 IEC/TS 60034-18-41 IEC 60216-3 IEC/TS 61251 IEC 61800-4 IEC 62068-1 IEC 62539

Adopt standards

IEC/TS 60034-18-42:2008