GB/T 6113.202-2008 Replaced National standards

GB/T 6113.202-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-2:Methods of measurement of disturbances and immunity—Measurement of disturbance power

GB/T 6113.202-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-2:Methods of measurement of disturbances and immunity—Measurement of disturbance power

Publish Date: 2008-01-12 Implement Date: 2008-09-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: GB/T 6113.202-2008
Standard Type: National standards
Standard Status: Replaced
is_force_gb: no
CCS Name: Electromagnetic compatibility
ICS Name: Electromagnetic compatibility (EMC)
Publish Date: 2008-01-12
Implement Date: 2008-09-01
Pages: 28 pages

Scope

This part is part 2-2 of the basic standard GB/T 6113 "Specifications for Radio Disturbance and Anti-Disturbance Measurement Equipment and Measurement Methods", which specifies the method of measuring disturbance power using an absorption clamp in the frequency range of 30 MHz to 1,000 MHz.

Development Information

Word Count: 52 Thousand words Pages: 28 pages

Same series standard

GB/T 6113.101-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1:Radio disturbance and immunity measuring apparatus—Measuring apparatus GB/T 6113.102-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-2:Radio disturbance and immunity measuring apparatus—Ancillary equipment—Conducted disturbances GB/T 6113.103-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-3:Radio disturbance and immunity measuring apparatus—Ancillary equipment—Disturbances power GB/T 6113.104-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-4:Radio disturbance and immunity measuring apparatus—Ancillary equipment—Radiated disturbances GB/T 6113.105-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-5:Radio disturbance and immunity measuring apparatus—Antenna calibration test sites for 30 MHz to 1 000 MHz GB/T 6113.201-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-1:Methods of measurement of disturbances and immunity—Conducted disturbance measurements GB/T 6113.203-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-3:Methods of measurement of disturbances and immunity—Radiated disturbance measurements GB/T 6113.204-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-4:Methods of measurement of disturbances and immunity—Immunity measurements

Replace the following standards

Superseded by the following standards

Referenced Standards

GB/T 4365-2003 Electrotechnical terminology—Electromagnetic compatibility GB 4343.1-2003 Electromagnetic compatibility—Requirements for household appliances, electric tools and similar apparatus—Part 1:Emission GB 4824-2004 Industrial, scientific and medical(ISM) radio-frequency equipment—Electromagnetic disturbance characteristics—Limits and methods of measurement GB/T 6113.101-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1:Radio disturbance and immunity measuring apparatus—Measuring apparatus GB/T 6113.103-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-3:Radio disturbance and immunity measuring apparatus—Ancillary equipment—Disturbances power GB/T 6113.201-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-1:Methods of measurement of disturbances and immunity—Conducted disturbance measurements GB/T 6113.203-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-3:Methods of measurement of disturbances and immunity—Radiated disturbance measurements GB/T 6113.204-2008 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-4:Methods of measurement of disturbances and immunity—Immunity measurements GB/Z 6113.3-2006 Specification for radio disturbance and immunity measuring apparatus and methods—Part 3:CISPR technical report GB/Z 6113.401-2007 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-1:Uncertainties,statistics and limit modelling—Uncertainties in standardized EMC tests GB/T 6113.402-2006 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-2:Uncertainties,statistics and limit modelling—Measurement instrumentation Uncertainty GB/Z 6113.403-2007 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-3:Uncertainties,statistics and limit modelling—Statistical considerations in the determination of EMC compliance of mass-produced GB 13837-2003 Sound and television broadcast receivers and associated equipment—Radio disturbance characteristics—Limits and methods of measurement ITU-R 推荐 BS.468-4

Adopt standards

CISPR16-2-2:2004

Related Standards