JJG 1009-2016 Replaced National Metrology and Inspection Regulations JJG

JJG 1009-2016 Personal Dose Equivalent HP(10) Monitors for X and γ Radiations

JJG 1009-2016 Personal Dose Equivalent HP(10) Monitors for X and γ Radiations

Publish Date: 2016-11-30 Implement Date: 2017-05-30 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: JJG 1009-2016
Standard Type: National standards
Standard Status: Replaced
is_force_gb: no
CCS Name: -
ICS Name: -
Publish Date: 2016-11-30
Implement Date: 2017-05-30
Pages: 24 pages

Scope

This regulation applies to the initial verification, subsequent verification, and in-use inspection of digital display monitors (hereinafter referred to as "monitors") worn on the human chest to measure, record, and alert the wearer of the personal dose equivalent HP(10) caused by external X and γ radiation. The applicable X and γ radiation energy range is 48 keV to 1.5 MeV. The monitors covered by this regulation must be small, integrated, wearable devices (excluding fixtures) with dimensions no exceeding: length 15 cm/width 8 cm/thickness 3 cm, with a total volume of 250 cm3; and a total weight, including accessories, no exceeding 200 g. This regulation does not apply to the verification of personal dose equivalent HP(0.07) monitors for weak penetrating X and γ radiation. This regulation does not apply to the verification of personal monitors for neutron and β radiation. This regulation does not apply to the verification of passive measurement devices such as film dosimeters, thermoluminescent dosimeters, or quartz wire electrostatic detectors.

Development Information

Word Count: 27 Thousand words Pages: 24 pages

Replace the following standards

Superseded by the following standards

Referenced Standards

GB/T 13161-2015 Radiation protection instrumentation—Measurement of personal dose equivalents Hp(10) and Hp(0.07) for X, gamma, neutron and beta radiations—Direct reading personal dose equivalent meters IEC 61526-2010 ICRU Report 47 GB/T 12162.1-2000 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1:Radiation characteristics and production methods GB/T 12162.2-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV GB/T 12162.3-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence GB/T 12162.3-2025 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence GB/T 12162.2-2025 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—Part 2:Dosimetry for radiation protection over the energy ranges from 8 keV to 1.3 MeV and 4 MeV to 9 MeV GB/T 12162.1-2025 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—Part 1:Radiation characteristics and production methods