T/BYXT 053-2023 Active Group standards

T/BYXT 053-2023 Technical Requirements for Rare Earth Dual-State Antibacterial and Epidemic Prevention Technology

T/BYXT 053-2023

Publish Date: 2023-03-20 Implement Date: 2023-04-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us
Price: $ 20.00
Download

Basic Information

Standard Code: T/BYXT 053-2023
Standard Type: Group standards
Standard Status: Active
is_force_gb: no
CCS Name: Technical management
ICS Name: Other standards related to disinfection and sterilization
Publish Date: 2023-03-20
Implement Date: 2023-04-01
Pages: 9 pages

Scope

Scope: This document specifies the terms and definitions, general principles, technical requirements, material requirements, evaluation and labeling of rare earth dual-state antibacterial and epidemic prevention technologies. This document applies to non-medical epidemic prevention and control technology requirements and antibacterial and epidemic prevention grade evaluation. Other infectious diseases transmitted through environmental surfaces and indoor air can be referred to for use in their elimination and prevention; Main technical content: 5.1 Static antibacterial technology requirements: After the environmental surfaces are coated or covered with rare earth antibacterial materials, the static antibacterial technical indicators on the material surface are shown in Table 1. Table 1: Static antibacterial technical indicators Project | Virus inhibition rate (%) | Antibacterial rate (%) | Safety a | SARS-COV-2 virus (WIVO4, GenBank: MN996528.1), with the test method being the novel coronavirus plaque inhibition method. a | Test strains and their numbers include Staphylococcus aureus (ATCC 6538), Escherichia coli (8099), and Candida albicans (ATCC 10231). The film-coating test method is performed according to Chapter 5.2.6 of the "Evaluation Methods for Antibacterial and Bacteriostatic Effects" (WS/T 650-2019). c | The toxicological test method for Class I disinfection products is performed according to Chapter 1.4.3.2 of the "Disinfection Technical Specifications". 5.2 Dynamic disinfection and purification technology requirements: After the ionic disinfection and purification equipment is installed and operated in the indoor environment, the technical indicators for dynamic disinfection and purification of the air within the effective coverage physical space are shown in Table 2. Table 2: Air dynamic disinfection and purification technical indicators Project | Disinfection factor | Plasma density distribution | Disinfection and sterilization r

Development Information

Pages: 9 pages

Related Standards

Contact Us