YY/T 0062.1-2024 Active Industry standards-Medicine

YY/T 0062.1-2024 Medical electrical equipment—Diagnostic X-rays—Part 1:Determination of quality equivalent filtration and permanent filtration

YY/T 0062.1-2024 Medical electrical equipment—Diagnostic X-rays—Part 1:Determination of quality equivalent filtration and permanent filtration

Publish Date: 2024-02-07 Implement Date: 2025-03-01 For services related to genuine standard inquiry, procurement, translation, and other related services in China, please Contact Us

Basic Information

Standard Code: YY/T 0062.1-2024
Standard Type: Industry standards
Standard Status: Active
is_force_gb: no
CCS Name: Medical radiation equipment
ICS Name: X-ray imaging equipment
Publish Date: 2024-02-07
Implement Date: 2025-03-01
Publisher: 国家药品监督管理局
Technical Committee: 全国医用电器标准化技术委员会医用X射线设备及用具分技术委员会(SAC/TC 10/SC 1)
Pages: 20 pages

Scope

本文件描述了X射线管组件的固有滤过和滤过材料质量等效滤过的测定方法,规定了X射线管组件在随附文件中的符合性声明和 X 射线管组件标记的要求,以及对滤过材料的指示和符合性声明要求。本文件适用于医疗诊断应用中高压150 kV以下的 X 射线管组件和滤过材料。对于高压大于50 kV,本文件仅适用于带有钨或钨合金靶的 X 射线管组件。

Development Information

Drafting Units:

辽宁省医疗器械检验检测院、辽宁省药品审评查验中心、西门子爱克斯射线真空技术(无锡)有限公司、复旦大学放射医学研究所、上海西门子医疗器械有限公司、杭州凯龙医疗器械有限公司、北京唯迈医疗设备有限公司、上海六晶科技股份有限公司、深圳市深图医学影像设备有限公司

Drafting Persons:

孟昭阳、迟戈、张振能、刘海宽、金玉博、刘璞、王越、余以智、刘文龙、朱玉斌、黄炜钦